室外机规格参数:
套餐 |
LP70A |
LP70B |
LP77 |
LP90A |
LP90B |
WP70 |
型号 |
2LPMXS3HV2C |
2LPMXS3HV2C |
2LPMXS3BHV2C |
2LPMXS4HV2C |
2LPMXS4HV2C |
2LPMXS3HV2C |
电源形式 |
单相,220V,50Hz |
容量(min~max) |
制冷 |
KW |
7.00(1.69~7.00) |
7.00(1.64~7.00) |
7.70(1.69~7.70) |
9.00(2.26~9.00) |
9.00(2.13~9.00) |
7.00(1.69~7.00) |
制热 |
KW |
9.70(1.76~9.70) |
9.70(1.68~9.70) |
10.00(1.76~10.00) |
11.00(2.65~11.00) |
11.00(2.42~11.00) |
9.70(1.76~9.70) |
消耗电力(min~max) |
制冷 |
KW |
3.02(0.48~3.02) |
3.02(0.47~2.56) |
2.83(0.48~3.07) |
3.30(0.59~3.30) |
3.48(0.58~3.41) |
2.98(0.48~2.98) |
制热 |
KW |
3.25(0.48~3.25) |
3.38(0.48~3.32) |
3.44(0.48~3.43) |
3.66(0.77~3.66) |
3.92(0.80~3.78) |
3.31(0.48~3.31) |
外形尺寸(H×W×D) |
mm |
735×936×300 |
735×936×300 |
735×936×300 |
770×900×320 |
770×900×320 |
735×936×300 |
运转音 |
制冷/制热 |
dB(A) |
50/51 |
50/51 |
50/51 |
54/54 |
54/54 |
50/51 |
重量 |
kg |
58 |
58 |
58 |
67 |
67 |
58 |
冷媒免充填长度 |
m |
30 |
30 |
30 |
40 |
40 |
30 |
配管最大长度(单根/长度和) |
m |
25/50 |
最大配管高低差(外机与内机/内机与内机) |
m |
15/7.5 |
运转范围 |
制冷 |
℃DB |
-5~46 |
制热 |
℃WB |
-15~15.5 |
注:能力测定条件: 1.上述室内机能力表示制冷时条件:室内回气温度27℃DB,19℃WB,室外温度35℃DB,24℃WB。冷媒配管长5m(水平)。 2.上述室内机能力表示制热时条件:室内回气温度20℃DB,室外温度7℃DB,6℃WB。冷媒配管长5m(水平)。 3.本网站记载的运转噪音的测试条件为公司内部规格条件,其值取用消音室换算所得出的最大值。 另外,在实际安装状态下,因受周围噪音及反射声的影响, 一般要高于本网站的记载值。
|